Box gutter gradients shall not be flatter than 1 200 for sole widths equal to or less than 600mm wide.
Box gutter sump size.
The minimum size of a sump is 400mm x 200mm minimum width of box gutter and 150mm deep.
The overflow diameter is the same as the downpipe diameter.
Downpipe eaves gutter long straight eaves gutters box gutter to rain water head box gutter vertical faces box gutter side o flow box gutter vertical o flow storm water pipe size storm water network overland flow path spitter upstream end custom rain water head.
The gutter collects the water and disposes of it through the drainpipe.
Experiment with this figure to get the depth of box gutter you require.
The suggested down pipe diameter is shown for reference purposes only.
They collect storm water before it is carried away by the downpipe and they also serve to catch any debris before it enters the downpipe.
A box gutter is given its name as it is usually boxed into the middle or edge of the roof.
For the associated box gutter outlet.
How much fall should i have on a box gutter.
Flow as the down pipe.
Colorbond box gutter measures 150mm x 150mm x 150mm.
The rectangular overflow width is equal to the box gutter width less 100mm.
The outlet must be no further than the diameter of the outlet to the centre of the outlet.
Learn more how to storm water design for building sites.
If this is the case the sump length will increase to accommodate the downpipe.
If draining to a sump with a vertical overflow in the middle of the box gutter use this calculator.
Where there is more than one overflow the design flow is divided equally and the spitter size shown will also be the suggested dp size for this fraction of the flow.
Sump with a side overflow device sumps do require an increase in the depth of flow in the box gutter and gutters are to be fitted with either.
Sumps are usually attached between a box gutter and the downpipe.
Sumps can be made to order but are commonly manufactured in either 100mm and 150mm depths.
This will give a sump depth about 150mm.
Trial box gutter width the minimum width allowed for commercial projects is 300mm for domestic projects 200mm.
Overflow devices need to discharge to the atmosphere in such a way as to prevent damage to buildings and property.
The code sump length is 600mm.
Choose an available dp size or any other size and enter that for the calculation of the sump.
50mm clearance on both sides.